Tripp Lite PDU 3-Phase Monitored ATS 208V 17.3kW 2 IEC 309 60A 1URM TAA

Mfg. Part: PDU360AT6G60 | CDW Part: 4490530 | UNSPSC: 39121017
Availability: 4-6 days Orders placed today will ship within 4-6 days
Warranties
Was $3,240.00
$2,084.77 Advertised Price
Lease Option ($61.50/month)
Note: Leasing is available to organizations only. Leasing is not available to individuals.
Product Details
  • Provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations
  • Dual 6.5 ft. input cords with IEC 309 60A Blue (3P+E) plugs connect to separate primary and secondary 3-phase power sources
  • Dynamic solid-state (TRIAC) automatic transfer switching
  • Requires separate installation of Tripp Lite PDU3V602D354
  • PDU3V602D354A or PDU3V602D354B power strip (sold separately)
  • power distribution unit / rack-mount power strip
View Full Product Details
Made For Each Other
Quick View
Total Price:

Product Overview

Main Features
  • Provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations
  • Dual 6.5 ft. input cords with IEC 309 60A Blue (3P+E) plugs connect to separate primary and secondary 3-phase power sources
  • Dynamic solid-state (TRIAC) automatic transfer switching
  • Requires separate installation of Tripp Lite PDU3V602D354
  • PDU3V602D354A or PDU3V602D354B power strip (sold separately)
  • power distribution unit / rack-mount power strip
Tripp Lite's patented PDU360AT6G60 17.3kW 3-Phase 208V ATS/Monitored PDU (U.S. Patent 9,467,006) provides rapid coordination of unsynchronized phases without dropping loads. It operates with the high efficiency and reliability required for data center applications.

Working in tandem with a required 0U vertical outlet accessory (sold separately; choose from PDU3V602D354, PDU3V602D354A or PDU3V602D354B), the 1U PDU360AT6G60 provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations.

Dual 6.5-foot input cords with IEC 309 60A Blue (3P+E) plugs connect to separate primary and secondary 3-phase power sources. The PDU constantly evaluates the power quality of both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 1 - 5 milliseconds should the primary source fail or become unstable to ensure your connected equipment operates without interruption.

Built-in Ethernet network interface allows remote access to the PDU for power monitoring, configuration, control and notifications via web browser, SSH, telnet or SNMP. Provides real-time load/current data with billing-grade accuracy (+/- 1 percent). Digital LED display indicates power availability, voltage, source A/B input status, output load and power factor.