Tripp Lite PDU Monitored Horizontal 5.8kw 208/240V L6-30R 2 L6-30P ATS 1URM

Mfg. Part: PDUMNH30HVAT | CDW Part: 3913316 | UNSPSC: 39121006
Availability: Call Call for availability
Warranties
Was $1,247.40
$803.98 Advertised Price
Lease Option ($23.72/month)
Note: Leasing is available to organizations only. Leasing is not available to individuals.
Product Details
  • 5.8kW Single-phase ATS Monitored PDU 1U Horizontal with L6-30R outlet and 2 L6-30P inputs
  • PDU / Power Distribution Unit / PDU Strip / Monitored PDU / rack pdu / pdus / datacenter pdu / network pdu / Horizontal PDU
  • Two single-phase L6-30P inputs with 10 ft. cords
  • L6-30R outlet for connecting single device or 0U vertical PDU
  • Automatic transfer switching within 1-5ms
  • Ethernet network interface for remote access
  • Digital LED display for real-time status monitoring
View Full Product Details
Made For Each Other
Quick View
Total Price:

Product Overview

Main Features
  • 5.8kW Single-phase ATS Monitored PDU 1U Horizontal with L6-30R outlet and 2 L6-30P inputs
  • PDU / Power Distribution Unit / PDU Strip / Monitored PDU / rack pdu / pdus / datacenter pdu / network pdu / Horizontal PDU
  • Two single-phase L6-30P inputs with 10 ft. cords
  • L6-30R outlet for connecting single device or 0U vertical PDU
  • Automatic transfer switching within 1-5ms
  • Ethernet network interface for remote access
  • Digital LED display for real-time status monitoring
The PDUMNH30HVAT 5.8kW Single-Phase 208/240V ATS/Monitored PDU provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 1U of space in EIA-standard 19-inch racks and features one L6-30R outlet—perfect for connecting a single device or a 0U 208/240V PDU with an L6-30P plug.

Dual 3.05 m (10-ft.) input cords with L6-30P plugs connect to separate primary and secondary single-phase power sources. The PDU constantly evaluates the power quality of both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 1–5 milliseconds should the primary source fail or become unstable to ensure your connected equipment operates without interruption.

Built-in Ethernet network interface allows remote access to the PDU for power monitoring, configuration, control and notifications via web browser, SSH, telnet or SNMP. Provides real-time load/current data with billing-grade accuracy (+/- 1 percent). Tiered access privileges allow both an administrator and a guest to log in. Automated alerts help prevent accidental overloads, power loss and downtime. Digital display indicates power availability, voltage, source A/B input status, output load and power factor, as well as temperature and humidity conditions with the optional ENVIROSENSE module (sold separately).