Tripp Lite PDU 3-Phase Vertical Strip ATS 208V 17.3kW 42 C13; 12 C19 0URM

Mfg.Part: PDU3V602D354A | CDW Part: 4586132 | UNSPSC: 39121017
Availability: 5-7 days
Warranties
Was $1,260.00
$895.75 Advertised Price
Advertised Price
Lease Option ($26.42/month) Lease Price Information
Note: Leasing is available to organizations only. Leasing is not available to individuals.
Product Details
  • 17.3kW 3-Phase PDU Strip 0U vertical 54 outlets accessory for select ATS PDUs
  • PDU / Power Distribution Unit / PDU Strip / ATS PDU / rack pdu / pdus / datacenter pdu / network pdu / Vertical PDU
  • Required for select Tripp Lite 3-Phase ATS PDUs
  • 54 single phase 208V outlets (42 C13 / 12 C19)
  • Supports up to 17.3kW total output
  • Simplifies load balancing with interlaced color-coded outlets
  • Supports 0U toolless vertical rack mounting
View Full Product Details
Better Together
Tripp Lite PDU 3-Phase Vertical Strip ATS 208V 17.3kW 42 C13; 12 C19 0URM
Quick View
Total Price:

Product Overview

Main Features
  • 17.3kW 3-Phase PDU Strip 0U vertical 54 outlets accessory for select ATS PDUs
  • PDU / Power Distribution Unit / PDU Strip / ATS PDU / rack pdu / pdus / datacenter pdu / network pdu / Vertical PDU
  • Required for select Tripp Lite 3-Phase ATS PDUs
  • 54 single phase 208V outlets (42 C13 / 12 C19)
  • Supports up to 17.3kW total output
  • Simplifies load balancing with interlaced color-coded outlets
  • Supports 0U toolless vertical rack mounting
The PDU3V602D354A 17.3kW 3-Phase Vertical PDU Outlet Strip is a required accessory option for Tripp Lite's PDU360AT6G60 and other 3-phase ATS PDUs that specify compatibility with this model. It's recommended for high-density equipment racks in data centers, server rooms and heavily configured equipment racks.

When used with the PDU360AT6G60, the PDU3V602D354A supports up to 17.3kW total output with 27.8A balanced maximum full load per output phase combination (L1 - L2, L2 - L3, L3 - L1) and 13.9A balanced maximum per breakered output load bank (C1 - C6).

The 42 C13 and 12 C19 single-phase 208V outlets receive power from the connected ATS PDU. The outlets are interlaced to help you balance loads by spreading connections across the phase combinations throughout the rack. Each outlet is numbered and color-coded to help you keep track of connected devices and which phase combination powers each. Dual 2.5-foot power cords, each with a special eight-position plug, connect directly to the PDU's rear receptacles.

The PDU3V602D354A's rugged all-metal housing mounts in compatible racks with no tools needed. Vertical 0U installation reduces cord clutter and improves airflow through the rack.