Tripp Lite PDU Switched ATS 120V 20A 5-15/20R 16 Outlet L5-20P Horizontal

Mfg.Part: PDUMH20ATNET | CDW Part: 1136739 | UNSPSC: 39121017
Availability: In Stock Ships today if ordered within 8 hrs 60 mins
Warranties
Was $910.80
$561.58 Advertised Price
Advertised Price
Lease Option ($16.57/month)
Note: Leasing is available to organizations only. Leasing is not available to individuals.
Product Details
  • 1.9kW single-phase ATS/Switched PDU 120V 1U Horizontal w/ 16 outlets and 12ft cords
  • PDU / Power Distribution Unit / PDU Strip / Switched PDU / rack pdu / pdus / datacenter pdu / network pdu / Horizontal PDU
  • Enables redundant A/B power option for single-corded network devices
  • Separate primary/secondary inputs connect to any two compatible power sources
  • 16 NEMA 5-15/20R outlets; 2 L5-20P/5-20P inputs 12ft cords
  • Built-in network interface and two digital visual current meters
View Full Product Details
Better Together
Quick View
Total Price:

Product Overview

Main Features
  • 1.9kW single-phase ATS/Switched PDU 120V 1U Horizontal w/ 16 outlets and 12ft cords
  • PDU / Power Distribution Unit / PDU Strip / Switched PDU / rack pdu / pdus / datacenter pdu / network pdu / Horizontal PDU
  • Enables redundant A/B power option for single-corded network devices
  • Separate primary/secondary inputs connect to any two compatible power sources
  • 16 NEMA 5-15/20R outlets; 2 L5-20P/5-20P inputs 12ft cords
  • Built-in network interface and two digital visual current meters
Tripp Lite Switched ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP, BOOTP and NTP. Switched PDU features include individually controllable output receptacles and built-in network interface. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability.